57a9b1fed7ba53d93d67d28cL&T Submersible Pump Controller 75.0 HP / 101.0 kW, MU G75 FASD Starter CS96451https://cdn1.storehippo.com/s/5673f4534c2cd39f78644ad1/ms.products/57a9b1fed7ba53d93d67d28c/images/57a9b1fed7ba53d93d67d28d/57a9b14a9eb8287b2a95f30c/webp/57a9b14a9eb8287b2a95f30c.jpgMax Motor Output at 415V, 3-Ph, 75.0 HP / 101.0 kW Relay Max Range (A) :– 66 – 110
Star Delta Starting is one of the methods of starting of 3-Phase pump-sets. In Fully Automatic version of Star-Delta (FASD) Starter, the changeover from star winding to delta winding is done with the help of a timer. L&T offers two variants of FASD – called starters and controllers.
FASD starters are basic electrical starters with contactor and relay combination for ON-OFF operation and overload protection of the pump-sets. Over and above the ON/OFF operation and overload protection features equipped in Controllers, it also provides additional features like Auto ON, indications of Supply ON/OFF and Pump ON/OFF, reading of real time voltage & current of pump with unique Dual analog meter. Single phasing protection relay (SPPR) inside Controller unit provides the advanced protection features viz. single-phasing prevention, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment for delayed operation of pump set. In Sheet –Steel Enclosure Type MF, MK, MU & MB (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)L&TMUG75CS96451
Max Motor Output at 415V, 3-Ph, 75.0 HP / 101.0 kW Relay Max Range (A) :– 66 – 110
Star Delta Starting is one of the methods of starting of 3-Phase pump-sets. In Fully Automatic version of Star-Delta (FASD) Starter, the changeover from star winding to delta winding is done with the help of a timer. L&T offers two variants of FASD – called starters and controllers.
FASD starters are basic electrical starters with contactor and relay combination for ON-OFF operation and overload protection of the pump-sets. Over and above the ON/OFF operation and overload protection features equipped in Controllers, it also provides additional features like Auto ON, indications of Supply ON/OFF and Pump ON/OFF, reading of real time voltage & current of pump with unique Dual analog meter. Single phasing protection relay (SPPR) inside Controller unit provides the advanced protection features viz. single-phasing prevention, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment for delayed operation of pump set. In Sheet –Steel Enclosure Type MF, MK, MU & MB (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)