57a9a79cd7ba53d93d67c497 L&T Submersible Pump Controller 10.0 HP / 7.5 kW, MU G10 DOL Starter SS95983 https://cdn1.storehippo.com/s/5673f4534c2cd39f78644ad1/ms.products/57a9a79cd7ba53d93d67c497/images/57a9a79cd7ba53d93d67c498/57a9a6b59eb8287b2a95f0e0/webp/57a9a6b59eb8287b2a95f0e0.jpg Max Motor Output at 415V, 3-Ph , 10.0 HP  / 7.5 kW
Relay Max Range (A) :– 13 – 21
 
Direct On-Line (DOL) method is the simplest starting method for 3-phase pump set. L&T offers two variants of DOL method – starter and controller.

DOL starters are basic electrical starters with contactors and relay for ON/OFF operation and overload protection of the pump set.
Over and above the ON/OFF operation and overload protection features equipped in Controllers, it also provides additional features like Auto ON, indications of Supply ON/OFF and Pump ON/OFF, reading of real time voltage & current of pump with unique Dual analog meter. Single phasing protection relay (SPPR) inside Controller unit provides the advanced protection features viz. single-phasing prevention, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment for delayed operation of pump set
In Sheet –Steel Enclosure Type MF, MK, MU & MB (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)
L&TMUG10SS95983
in stock INR 6460
L & T
1 1
XYZ Blog title
ABC Blog title here

L&T Submersible Pump Controller 10.0 HP / 7.5 kW, MU G10 DOL Starter SS95983

INR6,460.00


Sold By: bizliwala

Description of product

Max Motor Output at 415V, 3-Ph , 10.0 HP  / 7.5 kW
Relay Max Range (A) :– 13 – 21
 
Direct On-Line (DOL) method is the simplest starting method for 3-phase pump set. L&T offers two variants of DOL method – starter and controller.

DOL starters are basic electrical starters with contactors and relay for ON/OFF operation and overload protection of the pump set.
Over and above the ON/OFF operation and overload protection features equipped in Controllers, it also provides additional features like Auto ON, indications of Supply ON/OFF and Pump ON/OFF, reading of real time voltage & current of pump with unique Dual analog meter. Single phasing protection relay (SPPR) inside Controller unit provides the advanced protection features viz. single-phasing prevention, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment for delayed operation of pump set
In Sheet –Steel Enclosure Type MF, MK, MU & MB (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)