Features:
  • Conforms to IEC  60269-2, IS 13703 part2
  • Range: 2A to 800A, 415V, AC 50Hz
  • Type: Cylindrical (2A to 63A), DIN (63A to 800A) & Bolted (2A to 630A)
  • High Breaking Capacity: 100kA for type HN and 80 kA for Type HF/HG/HQ
Suitable for Type FN 100 / 125 / 160 /
FNX 100 / 125 / 160  S-D-F
& for HB 160 Fuse base
  
HRC Fuse Link range covers ratings from 2A to 800A. HRC Fuse-link range is available in 14x51 Cylindrical, DIN and BS type
High breaking capacity: 80kA for Cylindrical & BS Type & 100kA for DIN Type
The complete range conforms to IS 13703 (Part 2) / IEC 60269-2 standards
Let-through energy value of L&T’s fuse is extremely low; it leads to optimal selectivity for the cable size & downstream protection devices. Low power loss also leaded to low running cost & minimum heating.
Fuse blown indication is available through a red pop-up indicator
Suitable fuse base & fuse pulling handle are also available
L&THRCSF94946125A
in stockINR 1125
L & T
1 1
XYZ Blog title
ABC Blog title here
L&T HRC DIN Fuse Links Type HN 125A SF94946 Pack of 3 Pcs

L&T HRC DIN Fuse Links Type HN 125A SF94946 Pack of 3 Pcs

INR1,125.00


Sold By: bizliwala

Description of product

Size: 000
Features:
  • Conforms to IEC  60269-2, IS 13703 part2
  • Range: 2A to 800A, 415V, AC 50Hz
  • Type: Cylindrical (2A to 63A), DIN (63A to 800A) & Bolted (2A to 630A)
  • High Breaking Capacity: 100kA for type HN and 80 kA for Type HF/HG/HQ
Suitable for Type FN 100 / 125 / 160 /
FNX 100 / 125 / 160  S-D-F
& for HB 160 Fuse base
  
HRC Fuse Link range covers ratings from 2A to 800A. HRC Fuse-link range is available in 14x51 Cylindrical, DIN and BS type
High breaking capacity: 80kA for Cylindrical & BS Type & 100kA for DIN Type
The complete range conforms to IS 13703 (Part 2) / IEC 60269-2 standards
Let-through energy value of L&T’s fuse is extremely low; it leads to optimal selectivity for the cable size & downstream protection devices. Low power loss also leaded to low running cost & minimum heating.
Fuse blown indication is available through a red pop-up indicator
Suitable fuse base & fuse pulling handle are also available