57a99189d7ba53d93d67a86d L&T Fully Automatic Star-Delta Starters 50.0 HP / 37.5 kW, ML 3 FASD SS90730 https://cdn1.storehippo.com/s/5673f4534c2cd39f78644ad1/ms.products/57a99189d7ba53d93d67a86d/images/57a99189d7ba53d93d67a86e/57a990e69eb8287b2a95ec93/webp/57a990e69eb8287b2a95ec93.jpg Max Motor Output at 415V, 3-Ph, 50.0 HP / 37.5 kW
Relay Max Range (A) :– 28 – 42
 
Star Delta Starting is one of the methods of starting of 3-Phase pump-sets. In Fully Automatic version of Star-Delta (FASD) Starter, the changeover from star winding to delta winding is done with the help of a timer. L&T offers two variants of FASD – called starters and controllers.

FASD starters are basic electrical starters with contactor and relay combination for ON-OFF operation and overload protection of the pump-sets. Over and above the ON/OFF operation and overload protection features equipped in Controllers, it also provides additional features like Auto ON, indications of Supply ON/OFF and Pump ON/OFF, reading of real time voltage & current of pump with unique Dual analog meter. Single phasing protection relay (SPPR) inside Controller unit provides the advanced protection features viz. single-phasing prevention, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment for delayed operation of pump set.
In Sheet –Steel Enclosure Type MF, MK, MU & MB (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)
L&TMLFASDSS90730
in stockINR 33570
L & T
1 1
XYZ Blog title
ABC Blog title here
L&T Fully Automatic Star-Delta Starters 50.0 HP / 37.5 kW, ML 3 FASD SS90730

L&T Fully Automatic Star-Delta Starters 50.0 HP / 37.5 kW, ML 3 FASD SS90730

INR33,570.00


Sold By: bizliwala

Description of product

Max Motor Output at 415V, 3-Ph, 50.0 HP / 37.5 kW
Relay Max Range (A) :– 28 – 42
 
Star Delta Starting is one of the methods of starting of 3-Phase pump-sets. In Fully Automatic version of Star-Delta (FASD) Starter, the changeover from star winding to delta winding is done with the help of a timer. L&T offers two variants of FASD – called starters and controllers.

FASD starters are basic electrical starters with contactor and relay combination for ON-OFF operation and overload protection of the pump-sets. Over and above the ON/OFF operation and overload protection features equipped in Controllers, it also provides additional features like Auto ON, indications of Supply ON/OFF and Pump ON/OFF, reading of real time voltage & current of pump with unique Dual analog meter. Single phasing protection relay (SPPR) inside Controller unit provides the advanced protection features viz. single-phasing prevention, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment for delayed operation of pump set.
In Sheet –Steel Enclosure Type MF, MK, MU & MB (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)