57a851785e2d98ab0732334eL&T Fully Automatic Star-Delta Starters 175.0 HP / 130.0 kW ,MN 140 FASD SS94707https://cdn1.storehippo.com/s/5673f4534c2cd39f78644ad1/ms.products/57a851785e2d98ab0732334e/images/57a851785e2d98ab0732334f/57a850179d436abd5b03fd34/webp/57a850179d436abd5b03fd34.JPGMax Motor Output at 415V, 3-Ph, 175.0 HP / 130.0 kW Relay Max Range (A) :– 90 – 150
Star Delta Starting is one of the methods of starting of 3-Phase pump-sets. In Fully Automatic version of Star-Delta (FASD) Starter, the changeover from star winding to delta winding is done with the help of a timer. L&T offers two variants of FASD – called starters and controllers.
FASD starters are basic electrical starters with contactor and relay combination for ON-OFF operation and overload protection of the pump-sets. Over and above the ON/OFF operation and overload protection features equipped in Controllers, it also provides additional features like Auto ON, indications of Supply ON/OFF and Pump ON/OFF, reading of real time voltage & current of pump with unique Dual analog meter. Single phasing protection relay (SPPR) inside Controller unit provides the advanced protection features viz. single-phasing prevention, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment for delayed operation of pump set. In Sheet –Steel Enclosure Type MF, MK, MU & MB (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)L&TMNFASDSS94707
Max Motor Output at 415V, 3-Ph, 175.0 HP / 130.0 kW Relay Max Range (A) :– 90 – 150
Star Delta Starting is one of the methods of starting of 3-Phase pump-sets. In Fully Automatic version of Star-Delta (FASD) Starter, the changeover from star winding to delta winding is done with the help of a timer. L&T offers two variants of FASD – called starters and controllers.
FASD starters are basic electrical starters with contactor and relay combination for ON-OFF operation and overload protection of the pump-sets. Over and above the ON/OFF operation and overload protection features equipped in Controllers, it also provides additional features like Auto ON, indications of Supply ON/OFF and Pump ON/OFF, reading of real time voltage & current of pump with unique Dual analog meter. Single phasing protection relay (SPPR) inside Controller unit provides the advanced protection features viz. single-phasing prevention, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment for delayed operation of pump set. In Sheet –Steel Enclosure Type MF, MK, MU & MB (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)