Motwane DCM 10A originally manufactured by Multi Measuring Instruments Co. Ltd, Tokyo, Japan which is MULTI M140. Multi 140 Leakage Clamp Meter comes with 3 Year Replacement Warranty and Calibration Certificate traceable to National Standards in India.
Safety standard : Meets the requirements for double insulation to IEC 61010-1 (2010), IEC 61010-2-032 (2002) installation CategoryⅡ 600V phase to earth, CategoryⅢ 300V phase to earth. E.M.C. standard : The instrument meets EN 61326 (2006). Measuring method : Dual integration mode Measuring function : Leakage current and load current Display : 3.5 digital LCD, max. reading of 3200 Range : 0〜30mA/300mA/30A/300A (50/60Hz) Ranging : 2 ranges manuals Jaw opening capability : 40㎜f Over range indication : ”OL” mark on LCD readout Maximum indication : 3200 counts Low battery indication : 2.5V〜2.7V; ” “ mark on LCD readout Sampling : Approx. 2 times/s. (Digital display) Approx. 12 times/s. (Bargraph display) Data hold indication : ”DH” mark on LCD readout Auto power off : The meter is set to power off mode approx. 10 minutes after the power switch on. Withstanding voltage : AC3700V 1 minute max. (Between the core of CT and outer case) Operating temperature : 0℃ to 40℃, <80% RH (Non-condensing) Storage temperature : -10℃ to 60℃, <70% RH (Non-condensing) Power supply : LR-44 or SR-44×2 Power consumption : Approx. 5mW Battery life : Approx. 50 hours (LR44) Size : 64(W)×162(H)×23(D)㎜ Weight : Approx. 125g
Motwane DCM 10A originally manufactured by Multi Measuring Instruments Co. Ltd, Tokyo, Japan which is MULTI M140. Multi 140 Leakage Clamp Meter comes with 3 Year Replacement Warranty and Calibration Certificate traceable to National Standards in India.
Safety standard : Meets the requirements for double insulation to IEC 61010-1 (2010), IEC 61010-2-032 (2002) installation CategoryⅡ 600V phase to earth, CategoryⅢ 300V phase to earth. E.M.C. standard : The instrument meets EN 61326 (2006). Measuring method : Dual integration mode Measuring function : Leakage current and load current Display : 3.5 digital LCD, max. reading of 3200 Range : 0〜30mA/300mA/30A/300A (50/60Hz) Ranging : 2 ranges manuals Jaw opening capability : 40㎜f Over range indication : ”OL” mark on LCD readout Maximum indication : 3200 counts Low battery indication : 2.5V〜2.7V; ” “ mark on LCD readout Sampling : Approx. 2 times/s. (Digital display) Approx. 12 times/s. (Bargraph display) Data hold indication : ”DH” mark on LCD readout Auto power off : The meter is set to power off mode approx. 10 minutes after the power switch on. Withstanding voltage : AC3700V 1 minute max. (Between the core of CT and outer case) Operating temperature : 0℃ to 40℃, <80% RH (Non-condensing) Storage temperature : -10℃ to 60℃, <70% RH (Non-condensing) Power supply : LR-44 or SR-44×2 Power consumption : Approx. 5mW Battery life : Approx. 50 hours (LR44) Size : 64(W)×162(H)×23(D)㎜ Weight : Approx. 125g