L&T Submersible Pump Controller 50.0 HP / 27.5 kW, MU G50 FASD Starter CS96009
Max Motor Output at 415V, 3-Ph, 50.0 HP / 27.5 kW
Relay Max Range (A) :– 45 – 75
Star Delta Starting is one of the methods of starting of 3-Phase pump-set...INR -∞% OFF
INR 40,055L&T Submersible Pump Controller 75.0 HP / 101.0 kW, MU G75 FASD Starter CS96451
Max Motor Output at 415V, 3-Ph, 75.0 HP / 101.0 kW
Relay Max Range (A) :– 66 – 110
Star Delta Starting is one of the methods of starting of 3-Phase pump-s...INR -∞% OFF
INR 54,790L&T Submersible Pump Controller 75.0 HP / 101.0 kW, MU G75 FASD Starter CS96451
INR -∞% OFF
INR 54,790L&T Submersible Pump Controller 30.0 HP / 22.5 kW, MU G30 FASD Starter CS96008
Max Motor Output at 415V, 3-Ph, 30.0 HP / 22.5 kW
Relay Max Range (A) :– 30 – 50
Star Delta Starting is one of the methods of starting of 3-Phase pump-set...INR -∞% OFF
INR 25,075L&T Submersible Pump Controller 20.0 HP / 15.0 kW, MU G20H FASD Starter SS95975
Max Motor Output at 415V, 3-Ph, 20.0 HP / 15.0 kW
Relay Max Range (A) :– 28 – 42
Star Delta Starting is one of the methods of starting of 3-Phase pump-set...INR -∞% OFF
INR 15,180L&T Submersible Pump Controller 20.0 HP / 15.0 kW, MU G20H FASD Starter SS95975
INR -∞% OFF
INR 15,180L&T Submersible Pump Controller 20.0 HP / 15.0 kW ,MU G20 FASD Starter SS95984
Max Motor Output at 415V, 3-Ph, 20.0 HP / 15.0 kW
Relay Max Range (A) :– 13 – 21
Star Delta Starting is one of the methods of starting of 3-Phase pump-set...INR -∞% OFF
INR 12,405L&T Submersible Pump Controller 15.0 HP / 11.0 kW, MU G15 FASD Starter CS94091
Max Motor Output at 415V, 3-Ph, 15.0 HP / 11.0 kW
Relay Max Range (A) :– 13 – 22
Star Delta Starting is one of the methods of starting of 3-Phase pump-set...INR -∞% OFF
INR 10,600L&T Submersible Pump Controller 10.0 HP / 7.5 kW , MU G10H DOL Starter SS95974
Max Motor Output at 415V, 3-Ph , 10.0 HP / 7.5 kW
Relay Max Range (A) :– 28 – 42
Direct On-Line (DOL) method is the simplest starting method for 3-phase p...INR -∞% OFF
INR 7,560L&T Submersible Pump Controller 10.0 HP / 7.5 kW, MU G10 DOL Starter SS95983
Max Motor Output at 415V, 3-Ph , 10.0 HP / 7.5 kW
Relay Max Range (A) :– 13 – 21
Direct On-Line (DOL) method is the simplest starting method for 3-phase p...INR -∞% OFF
INR 6,460L&T Submersible Pump Controller 6.0 HP / 4.5 kW, MU G6 DOL Starter SS97756
Max Motor Output at 415V, 3-Ph , 6.0 HP / 4.5 kW
Relay Max Range (A) :– 9 – 14
Direct On-Line (DOL) method is the simplest starting method for 3-phase pum...INR -∞% OFF
INR 5,435